Send Message
Home ProductsENT Plasma Generator

Mechan New Generation of Plasma Generator for Minimally Invasive ENT Surgery -Turbinate Channeling and Ablation

Mechan New Generation of Plasma Generator for Minimally Invasive ENT Surgery -Turbinate Channeling and Ablation

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation
Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation
Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation
Product Details:
Place of Origin: China
Brand Name: MECHAN
Certification: CE, ISO 13485
Model Number: PLA-700
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD
Packaging Details: Carton
Delivery Time: 5-8 work days
Payment Terms: T/T, L/C
Supply Ability: 10000 set per year
Contact Now
Detailed Product Description
Application: Ears, Eyes, Nose And Throat Surgical Equipment Advantage: Minimally-invasive Surgery, Less Bleeding,low Working Temperature
Certificate: CE, ISO13485 Effect: Cutting, Ablation, Coagulation, Hemostasis
Color: White, Gray Weight: 7kg
High Light:

Minimally Invasive ENT Plasma Generator

,

Turbinate Reduction ENT Plasma Generator

                                                  Mechan Plasma Generator for  minimally Invasive  ENT surgery  

                                                          -Turbinate Channeling and Ablation

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 0

 

Product Description

*Bipolar or multi-polar cutting, low temperature ablation, resection, hemostasis, and coagulation, in minimally-invasive, safe and reliable way.

*Two modes are available, ABLATION mode for channeling, resection,hemostasis and ablation while PLACOAG mode for hemostasis and         coagulation.

* Different types of probes available for options. The length, diameter, radian, energy level of probes are designed to meet the requirements of different locations and diseases.

*Supplied with the function and accessories for suction and resection,good at CAUP,UPPP,Tonsillectomy, Adenoidectomy,Papilloma, Polypus, other Tumor surgeries, and lesion tissues at concealed and deep locations(e.g. deep laryngeal and tongue base).

*Adjustable host machine audible call. Working audible call of ABLATION and PLACOAG is different to avoid stepping on the wrong foot pedal.

* Automatic detection technology of impedance and energy. Monitoring system of thermal damage depth.

*Generator can automatically identify the connection status of handle and footswitch.

* Plasma density at the probe tip is detected.

ABLATION and PLACOAG modes can be started-up or switched through footswitch.

* Default power level can be automatically set up against successful connection of footswitch.

 

Place of Origin: Sichuan, China
Brand Name: MECHAN
Model Number: PLA-700
Technology: Cold Radiofreqency Plasma
Feature: Low temperature minimally invasive
Instrument classification:

Class III

 

Plasma Surgery System Advantages:


1. Compared with traditional surgical methods (like electrosurgery and laser), there is no electric current passes through human body, and temperature at the working surface is only 40 – 70 ℃, the thermal injury to adjacent tissue is less. When using the recommended energy levels, the ablation and coagulation depths are controlled at ≤50μm.

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 1
2. In coagulation, the low temperature plasma can control the temperature to 40 – 70 ℃ precisely, which not only ensures the shrinking of helical structure of collagen molecule but also maintains vitality of cells.

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 2
3. Compared with traditional surgical methods (like electrosurgery and laser), plasma has less thermal energy, lighter thermal injury, shorter wound healing time, and slimmer chance of wound bleeding and scar.

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 3
4.
Compared with traditional surgical methods (like electrosurgery and laser), intraoperative pain of patient has decreased obviously, and the post-operation inflammatory rate decreased significantly. During surgery, surgeon can stop bleeding at the same time of resection without using any other tool for assistant.

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 4Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 5

5.Compared with traditional surgical methods (like electrosurgery and laser), PLA -700 is featured with less blood loss, lighter aching feeling, better therapeutic effect,quicker recovery.Compared with traditional surgical methods (like electrosurgery and laser), PLA -700 is featured with less blood loss, lighter aching feeling, better therapeutic effect,quicker recovery.

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 6  Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 7

Supply Ability

Supply Ability: 10000 Sets per Year

 

Packaging & Delivery

Packaging Details: Carton packaging
Port: Chengdu
Lead Time:

Quantity(Sets) 1 - 10 >10
Est. Time(days) 3 To be negotiated

 

Factory Overview

Mechan New Generation of Plasma Generator for  Minimally Invasive  ENT Surgery -Turbinate Channeling and Ablation 8

Contact Details
Chengdu Mechan Electronic Technology Co., Ltd

Contact Person: Amanda

Send your inquiry directly to us
Other Products