Adeno-tonsillectomy Low-temperature Plasma Radiofrequency ENT Probe Coblation Wands
Indications:
Tonsillectomy, adenoidectomy, UPPP, CAUP, and the surgery of lesion tissues at narrow spaces like nasal cavity.
Parameters:
Degree | 35° |
Length | 120mm |
Outer diameter | 4.4mm |
Saline tube | Yes |
Cable integrated | Yes |
Article number | EB404M07-1 |
Features:
The PLA404 electrode has a smaller diameter than PLA401 and PLA402, but has the same usage and purpose. Smaller shaft profile and minimize occurrence of probe tip clogging.
Plasma Surgery System PLA series products inspection items:
Biocompatibility: cytotoxicity | EN ISO 10993-5:2009 |
Biocompatibility: sentitization, skin irritation test | EN ISO 10993-10:2009 |
Test of packaging materials: vacuum leaks, pigment infiltration, agar attack, seal stripping / aging experiment | EN ISO 11607-1:2009 |
Safety regulations Third Edition | EN 60601-1:2006/AC:2012 |
Obtained the CE Certificate and Rohs certificate, Passed the EMC detection |
IEC 62321:2008 IEC 60601-1-2:2007 |
Special standard | EN 60601-2-2:2009 |
Plasma Surgery System Advantages:
1. In comparison with traditional surgical methods (like electrosurgery and laser), there is no electric current passes through human body, and temperature at the working surface is only 40 – 70 ℃, the thermal injury to adjacent tissue is less. When using the recommended energy levels, the ablation and coagulation depths are controlled at ≤50μm.
2. In coagulation, the low temperature plasma can control the temperature to 40 – 70 ℃ precisely, which not only ensures the shrinking of helical structure of collagen molecule but also maintains vitality of cells.
3. In comparison with traditional surgical methods (like electrosurgery and laser), plasma has less thermal energy, lighter thermal injury, shorter wound healing time, and slimmer chance of wound bleeding and scar.
4. In comparison with traditional surgical methods (like electrosurgery and laser), intraoperative pain of patient has decreased obviously, and the post-operation inflammatory rate decreased significantly. During surgery, surgeon can stop bleeding at the same time of resection without using any other tool for assistant.
Contact Person: ellena
Electrical Surgical Unit Plasma Surgical Device For Urethratresia Surgery
Dysuresia Plasma Surgical Device With Plasma Ablation Wand And Urology Electrode
Easy Recovering Cold Plasma Device , Electrical Plasma Ablation Wand For Laparotomy
Urology Electrode Plasma Surgical Device For BPH Benign Prostate Hyperplasia
Two Ablation Modes Bipolar Surgical Instrument For Turbinate / Soft Palate
UPPP / Tonsillectomy ENT Plasma Generator With Plasma Surgery System
RF Generator ENT Plasma Generator For Laryngeal / Papilloma Resection
Adnoidectomy / Tonsillectomy ENT Plasma Generator With Multi Function Probe
Low Temperature RF Plasma Electrical Surgical Unit, minimal invasive For Nucleoplasty Treatment
Inter Vertebral Treatment Electrical Surgical Unit , Low RF, Low temperature Plasma Surgery System
Plasma Surgery System, Electrical Surgical Unit,Ablation For Inter Vertebral Treatment