PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate

PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate

  • PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate
  • PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate
  • PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate
PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate
Product Details:
Place of Origin: CHINA
Brand Name: MECHAN
Certification: CE, ISO13485
Model Number: PLA201
Payment & Shipping Terms:
Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: carton
Payment Terms: T/T, L/C
Supply Ability: 100000 sets per year
Contact Now
Detailed Product Description
Ablation: Adjustable From 1 To 10 Coagulation: Adjustable From 1 To 10
Application: BPH, TURP, Bladder Tumor Advantage: MIS, Low Temperature
Warranty: 24 Months After Sterilization Shaft Length: 286mm
Usage: Ablation, Cutting, Resection, Hemostasis Feature: One Time Use
High Light:

arthrocare coblation wand

,

radio frequency probe

Procise Plasma Wand BPH Surgery Probe BPH Plasma Electrode Prostate

 

Product Introduction

 

PLA201 is "Gold standard" single ring design, connect with PLA-600 Urology Plasma Surgery System, into the treatment of TURP, BPH, Bladder tumor etc.. It has the function of cutting, ablation, hemostasis and coagulation.

 

Product Tip Picture

 

PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate 0

 

Product Character

 

  • Really exfoliate along the cavity of the surgical capsule
  • Block blood flow thoroughly, clear vision, clear boundaries, not easy to accidental injury
  • The glands are completely removed without trimming the tip, which is not easy to cause urinary incontinence. There will be some patients with pseudo-urinary incontinence, which will return to normal within 3 months after surgery

 

Product Advanatages

 

  • Safety: Compared with traditional surgical methods (such as: electric knife, laser), the current does not flow through the human body, the working surface temperature is only 40 ° C to 70 ° C, and the surrounding tissue is less thermally damaged. When used in the recommended energy range, the cutting and ablation depth is controlled to ≤50μm.
  • Minimally Invasive: Compared with traditional surgical methods (such as electric knife, laser), it has less heat, reduces tissue thermal damage, reduces wound healing time, reduces wound bleeding and scar formation
  • High Efficiency: Compared with traditional surgical methods (such as: electric knife, laser), the patient's pain during surgery is significantly reduced, and the incidence of postoperative inflammation is significantly reduced. During the surgery, the doctor stops bleeding while cutting, and does not need other hemostasis tools.

 

System Set Up

 

Description Remark
Manufacturer Logo MECHEN Brand.
Working Frequency 50Hz
Receptacle of Footswitch Connects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment Handle Connects with the treatment accessories.
Power Switch System start power button. “O” means power off; “I” means power on.
ABLATION mode Selector Select ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe Connection LED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch Connection LED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down Button The number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

 

 

Anesthesia


Epidural anesthesia is usually used. You can also choose spinal anesthesia or general anesthesia.

 

Cutting Principle

 

Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.

 

Treatment Diseases 

 

1. Benign prostatic hyperplasia of prostate: large adenoma, medium-sized adenoma, small adenoma

2. Small and medium-sized adenoma combined with stones;

3. Fibrotic prostatitis;

4. Prostate cancer.

 

Storage Condition

 

Electrodes shall be stored in environment of humidity less than 80%. no corrosive gas, well vented room. Taking complete protection to electrodes.

PLA201 Procise Plasma Wand Radiofrequency Probe BPH Plasma Electrode Prostate 1