Place of Origin: | CHINA |
Brand Name: | MECHAN |
Certification: | CE, ISO13485 |
Model Number: | PLA402 |
Minimum Order Quantity: | Negotiation |
---|---|
Price: | Negotiation |
Packaging Details: | carton |
Payment Terms: | T/T, L/C |
Supply Ability: | 100000 sets per year |
Ablation: | Adjustable From 1 To 10 | Coagulation: | Adjustable From 1 To 10 |
---|---|---|---|
Application: | Tonsillectomy, Adenoidectomy, CAUP, UPPP | Advantage: | Minimally Invasive, Low Temperature |
Warranty: | 24 Months After Sterilization | Shaft Length: | 120mm |
Usage: | Ablation, Cutting, Resection, Hemostasis | Feature: | Disposable |
Probe Angle: | 35° | ||
High Light: | ent surgical instruments,portable plasma wand |
Tonsillectomy Plasma Wand ENT Probe For Minimally Invasive Plasma Surgery
Product Introduction
PLA402 is design specially for Tonsillectomy, Adenoidectomy, CAUP, UPPP, and nasal cavity lesion tissue treatment. Tonsillary and adenoidectomy, UPPP, CAUP, and nasal cavity lesion treatment. The diameter is thinner, which is more convenient for children to use; the liquid enters and exits in two channels and is separated separately, which can effectively prevent the cutter head from being blocked, and the electrode surface of the cutter head is plated with special metal for longer use. It has the function of cutting, ablation, hemostasis and coagulation. It is connect with PLA-700 ENT plasma surgery system to perform the operation.
Product Tip Picture
Product Application
Product Advanatages
System Set Up
Description | Remark |
Manufacturer Logo | MECHEN Brand. |
Working Frequency | 50Hz |
Receptacle of Footswitch | Connects with Footswitch which determines ablation or coagulation mode. |
Receptacle of Treatment Handle | Connects with the treatment accessories. |
Power Switch | System start power button. “O” means power off; “I” means power on. |
ABLATION mode Selector | Select ABLATION mode 1 or 2 Output waveform. |
Indicator of Treatment Probe Connection | LED turns on green when the probe cable is connected and turns on red when it is not connected. |
Indicator of Footswitch Connection | LED turns on green when the footswitch cable is connected and turns on Red when it is not connected. |
ABLATION Power Setting Display |
Shows the preset ABLATION output value in two digits. “01” with Min. power output, and “10” with the highest output. |
Ablation Output Power Up/Down Button | The number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode. |
Anesthesia
General anesthesia
Cutting Principle
Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.
Treatment Diseases
Tonsillectomy, Adenoidectomy, CAUP, UPPP and the soft tissue at narrow spaces like nasal cavity.
Storage Condition
Electrodes shall be stored in environment of humidity less than 80%. no corrosive gas, well vented room. Taking complete protection to electrodes.
Contact Person: Ivy
Electrical Surgical Unit Plasma Surgical Device For Urethratresia Surgery
Dysuresia Plasma Surgical Device With Plasma Ablation Wand And Urology Electrode
Easy Recovering Cold Plasma Device , Electrical Plasma Ablation Wand For Laparotomy
Urology Electrode Plasma Surgical Device For BPH Benign Prostate Hyperplasia
Two Ablation Modes Bipolar Surgical Instrument For Turbinate / Soft Palate
UPPP / Tonsillectomy ENT Plasma Generator With Plasma Surgery System
RF Generator ENT Plasma Generator For Laryngeal / Papilloma Resection
Adnoidectomy / Tonsillectomy ENT Plasma Generator With Multi Function Probe
Low Temperature RF Plasma Electrical Surgical Unit, minimal invasive For Nucleoplasty Treatment
Inter Vertebral Treatment Electrical Surgical Unit , Low RF, Low temperature Plasma Surgery System