Place of Origin: | China |
Brand Name: | MECHAN |
Certification: | CE, ISO |
Model Number: | PLA-600 |
Minimum Order Quantity: | 1 SET |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden Box |
Delivery Time: | 1-5weeks |
Payment Terms: | T/T, L/C, Western Union |
Supply Ability: | 100 units per day |
Brand: | MECHAN | Model No.: | PLA-600 |
---|---|---|---|
Applying Field: | Urology Department | Color: | Orange |
Net Weight: | 7KG | Compatible Probe: | PLA201, PLA202, PLA204, PLA205, PLA207 |
Warranty: | 2 Years | Packing: | Paper Box |
High Light: | utm testing machine,digital utm machine |
Urology Plasma Surgery System for BPH Treatment
Product Introduction
This PLA-600 Model Urology Plasma Surgery System are designed to appliy into the field of urology. On the front panel, there are two working modes, Ablation mode and Coagulation mode. Which can be adjust from 1 to 10 level by push the plus + or reduce - button. It is widely applying to BPH and Bladder tumor treatment.
Product Diagram
Technical Parameter
Input Volts |
198-240V 50Hz 100-120V 60Hz Export device could convert automatically per customer requirements |
Output Power |
Ablation or resection: ≤351W Coagulation or hemostasis: ≤111W |
Working Frequency | 100 KHz ± 10% |
Dimension | 405*440*130mm (L*W*H) |
Working Mode |
Ablation and resection: level 1-10 Coagulation: level 1-10 |
Weight | 7.0kg |
Product Advanatages
System Set Up
Description | Remark |
Manufacturer Logo | MECHEN Brand. |
Pads | Insulation and support on the surface. |
Receptacle of Footswitch | Connects with Footswitch which determines ablation or coagulation mode. |
Receptacle of Treatment Handle | Connects with the treatment accessories. |
Power Switch | System start power button. “O” means power off; “I” means power on. |
ABLATION mode Selector | Select ABLATION mode 1 or 2 Output waveform. |
Indicator of Treatment Probe Connection | LED turns on green when the probe cable is connected and turns on red when it is not connected. |
Indicator of Footswitch Connection | LED turns on green when the footswitch cable is connected and turns on Red when it is not connected. |
ABLATION Power Setting Display |
Shows the preset ABLATION output value in two digits. “01” with Min. power output, and “10” with the highest output. |
Ablation Output Power Up/Down Button | The number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode. |
System Component
1). One tabletop generator device
2). One reusable and non-sterile power supply cable.
3). One reusable and non-sterile footswitch.
4). One reusable and non-sterile treatment handle which is for foot control.
5). Treatment probes.
Storage Condition
This device should be stored in a well-ventilated room without corrosive gas. The height above ground and the distance from wall should be above 30cm. Stack limit is 6 cases. Before being stored for a long time, it should be cleaned thoroughly for proper packing and storage. And it should also be taken out for power up every year, in order to avoid it from moisture, mildew or even damage. The suitable weather and environment condition is as below:
1. Temperature: -40℃~+55℃;
2. Relative humidity: ≤90%;
3. Atmospheric pressure: 50kPa~106kPa
Contact Person: Ivy
Tel: +8613730856410
Electrical Surgical Unit Plasma Surgical Device For Urethratresia Surgery
Dysuresia Plasma Surgical Device With Plasma Ablation Wand And Urology Electrode
Easy Recovering Cold Plasma Device , Electrical Plasma Ablation Wand For Laparotomy
Urology Electrode Plasma Surgical Device For BPH Benign Prostate Hyperplasia
Two Ablation Modes Bipolar Surgical Instrument For Turbinate / Soft Palate
UPPP / Tonsillectomy ENT Plasma Generator With Plasma Surgery System
RF Generator ENT Plasma Generator For Laryngeal / Papilloma Resection
Adnoidectomy / Tonsillectomy ENT Plasma Generator With Multi Function Probe
Low Temperature RF Plasma Electrical Surgical Unit, minimal invasive For Nucleoplasty Treatment
Inter Vertebral Treatment Electrical Surgical Unit , Low RF, Low temperature Plasma Surgery System
Plasma Surgery System, Electrical Surgical Unit,Ablation For Inter Vertebral Treatment